How to Replace a 57mm NEMA23 Stepper Motor on a Tronxy X5SA-600 Large-Format Printer

How to Replace a 57mm NEMA23 Stepper Motor on a Tronxy X5SA-600 Large-Format Printer

A step-by-step guide to swapping a tired 57 mm NEMA 23 stepper on the X5SA-600 carriage: unbolting, uncoupling, wiring, current setting and a first-run test.

Verdict Up Front

Verdict up front: replacing a 57 mm NEMA 23 stepper on a large-format printer is a mechanical job, not a soldering job. The process is power off, uncouple the old motor, unbolt it, fit the Tronxy SL57STH56-2804A, re-couple, wire the four leads, set the driver current to 2.8 A, and jog-test. Most of the work is alignment and the first-run test, not the swap itself.

The boundary is safety. Work only with the printer unplugged. The motion rail is spring-loaded and the supply holds mains voltage on its primary side even when the printer is off. Label the four motor wires before you disconnect them so the phase pairing is restored exactly.

Across a maker whose axis has started skipping steps, a workshop doing a scheduled motor swap, and a retrofitter upgrading to a known NEMA 23 replacement, the same sequence applies: document, remove, fit, align, tune, test.

The second boundary is the driver current. A 2.8 A class motor will not perform at its rating unless the driver current is set correctly. Measure the VREF or use the board's current-setting menu after install, not before.

Hand unbolting an old NEMA23 stepper from a large-format printer gantry

What You Need Before You Start

The replacement motor. The Tronxy SL57STH56-2804A is the 57 mm NEMA 23 class motor specified for the X5SA-600, at $36.99 as SKU CXY03.03.0041. Confirm the flange, shaft and lead with the merchant before you begin, since the listing does not publish shaft diameter or connector pinout.

Tools. A set of hex keys, a screwdriver, a multimeter for the current check, and zip ties for the lead. A second person to hold the gantry while you uncouple is useful on a large machine.

Paper and tape to label. Mark the four wires A+, A-, B+, B- as you disconnect them. If you mix the phases, the motor will buzz and not turn; reversing one pair fixes direction, but swapping a phase pair makes it useless.

Bench space. Lay the new motor, the screws and the old motor side by side. Compare the flange holes and the shaft before you unbolt the old one, so you know the fit is correct.

Step 1 — Power Off and Document

Unplug the printer. Do not rely on the soft switch; pull the mains lead. Wait two minutes for the capacitors to drain.

Take a phone photo of the wire routing and the driver current setting before you touch anything. That photo is your rollback if something goes wrong.

Label the four motor wires. The listing does not publish the color-to-phase mapping, so use continuity: two wires that show resistance between them are one phase. Mark them as pair A and pair B.

Note the current-setting value on your driver. If you know the old motor rating, write it down. You will set the new motor to its own 2.8 A rating, not copy the old value.

Hands unscrewing an old stepper motor from a 3D printer carriage

Step 2 — Uncouple and Unbolt

Loosen the coupler set screw on the leadscrew or belt side. The coupler connects the motor shaft to the leadscrew; do not force it. If it is stuck, loosen the set screw and twist gently.

Remove the four motor mounting screws. On a 57 mm NEMA 23, these are evenly spaced around the flange. Support the motor as you remove the last screw so it does not drop onto the bed.

Lift the motor straight out. Disconnect the four-wire lead from the driver board. Keep the old motor for reference; compare the shaft and flange before you discard it.

Inspect the bracket. Clean any dust from the mounting holes and check that the bracket is not bent. A bent bracket will cause misalignment even with a new motor.

New silver NEMA23 stepper aligned to carriage mounting holes

Step 3 — Fit and Align the New Motor

Offer the Tronxy SL57STH56-2804A to the bracket. The 57 mm flange should drop onto the four holes. If it does not, do not force it; check whether you have the right flange or whether the bracket is blocked.

Start the four screws by hand. Do not tighten one fully before the others are in. Snug them in a diagonal sequence so the motor seats flat against the bracket.

Re-couple the shaft to the leadscrew. Slide the coupler onto the shaft and tighten the set screw. The shaft should bottom out in the coupler; if it does not, check shaft length with the merchant.

Check alignment. The coupler should sit flat with no lateral gap. A misaligned coupler causes vibration, noise and lost steps. Tighten the screws to a firm but not brutal torque.

Step 4 — Wire and Set the Current

Connect the four wires to the driver in the same pairing you documented. Pair A goes to one phase, pair B to the other. If the motor turns the wrong direction when you jog, reverse one pair.

Set the driver current to the 2.8 A rating. Use your board's current-setting menu or measure the VREF with a multimeter. The listing does not publish the coil resistance or the VREF formula, so confirm the procedure with the merchant.

Do not set the current higher than the rating. Over-driving a NEMA 23 causes heat and can demagnetize it over time. Under-driving loses torque. The 2.8 A rating is the target.

Route the lead away from the belt, the rails and the hotend. Secure it with zip ties where it turns a corner. A chafed lead is the most common post-install failure.

NEMA23 stepper installed on a large-format gantry ready for testing

Step 5 — First-Run Test

Plug in the printer. Do not start a long print. Jog the axis at low speed first. The motor should move smoothly with no grinding noise.

Ramp up the speed and acceleration. Watch for skipped steps or stalls. If the motor hums but does not turn, the phase pairing is wrong; swap one pair and try again.

Run a short ten-minute test move. Feel the motor case; it should be warm but not too hot to hold. If it is too hot, lower the current. If it runs stone cold, you may be under-driving.

Run a calibration test. Home the axis, move a known distance, and check the position. If the step-per-unit setting is unchanged, the new motor should hold position exactly.

Common Problems After a Swap

Motor buzzes and does not turn. The phase pairing is wrong. Two wires from the same phase are split across both driver channels. Check continuity and re-pair.

Axis moves backwards. Reverse one phase pair. This is a one-minute fix.

Lost steps at high acceleration. The current may be too low, or the acceleration too aggressive. Turn up the current to the rating and lower the acceleration until smooth.

Vibration or noise. The coupler is misaligned. Re-seat the motor and re-tighten the set screws. A bent bracket also causes vibration.

Motor runs hot. The current is too high or the motor is overloaded. Lower the current to the rating and check the load.

Maintenance After the Swap

After the first hundred hours, re-check the coupler set screws and the motor mounting screws. Vibration can loosen them.

Keep the motor and lead clean. Blow out dust from the cooling fins every few months. A dusty motor runs hotter.

Label the spare. If you keep a spare NEMA 23 on the shelf, label it with the model and the 2.8 A current setting so a future swap is fast.

Record the install. Note the date and the current setting in your maintenance log. A motor that fails early after install points to a wiring or alignment issue, not a bad part.

Questions to Ask Before You Order

Is my bracket the 57 mm NEMA 23 pattern? The listing specifies the X5SA-600; confirm the flange before ordering.

What is the shaft diameter? The listing does not publish it; confirm with the merchant and size your coupler.

Can my driver supply 2.8 A? If not, upgrade the driver before the swap.

Do I have the right coupler? Compare the old shaft to the new one; if the diameter differs, buy a new coupler.

Removing the Old Z-Axis Motor

Power off the printer and unplug it. Wait for the power supply capacitors to drain before touching any wires. On a Tronxy X5SA-600, the Z-axis motor sits at the top of the vertical extrusion, coupled to the leadscrew.

Unscrew the four mounting bolts on the motor face. Support the motor as you remove the last bolt so it does not fall. The leadscrew may stay in the nut block; if it drops, catch it.

Unplug the motor connector from the mainboard. Label the plug with a piece of tape so you remember which header it came from. The four wires form two phase pairs; do not cut or desolder them unless the connector is damaged.

Inspect the leadscrew and the coupler. Look for wear, play or a bent section. If the coupler is cracked, replace it. A worn coupler transmits vibration to the new motor and will cause misalignment.

Fitting the Tronxy NEMA 23 Replacement

Offer the SL57STH56-2804A to the bracket. The 57 mm NEMA 23 flange should match the existing holes on a printer that originally used a NEMA 23. If your printer used a NEMA 17, the holes will not line up and you need a bracket adapter.

Start the four bolts by hand and tighten them diagonally in sequence. This seats the motor flat against the bracket. A tilted motor causes coupler misalignment, which causes vibration and noise.

Slide the coupler onto the motor shaft. The shaft should bottom out in the coupler. Tighten the set screw on the motor shaft side, then align the leadscrew and tighten the set screw on the leadscrew side.

Check alignment by turning the leadscrew by hand. The motor should rotate freely with no grinding or binding. If it binds, re-seat the motor and re-tighten.

Wiring and Current Verification

Connect the four wires to the driver. Use a multimeter on resistance to identify the two phase pairs: two wires that read a few ohms are one phase. Pair A goes to the A terminals, pair B to the B terminals.

Set the driver current to the 2.8 A class rating. The listing does not publish the VREF formula, so confirm the exact trim value with the merchant. A 2.8 A coil on a driver set to 1.5 A will underperform and stall; set to 4 A will overheat.

If the Z axis moves the wrong direction, reverse one phase pair or invert the direction in firmware. This is a one-minute fix.

Route the lead away from the leadscrew and the moving bed. Secure it with a zip tie. A chafed lead causes intermittent stalls and is a fire risk near the hotend.

Post-Install Alignment Check

After the mechanical swap, check the alignment three ways: by eye, by hand, and by test print.

By eye: look at the motor face and the bracket. The motor should sit flat with no gap at any corner. A gap means a bent bracket or a misaligned motor.

By hand: turn the leadscrew with the motor unplugged. It should turn smoothly with no grinding. If it binds, the coupler is misaligned.

By test print: print a tall calibration cube. The layers should be even. If you see banding or wobble, the Z axis needs re-alignment.

Firmware Settings to Verify

After the swap, confirm the step-per-unit value. The motor is still 200 steps per revolution at 1.8 degrees, so the step-per-unit does not change unless the leadscrew pitch changed.

Confirm the current setting. The listing states 2.8 A class. Set the driver to match. The VREF formula is not published; confirm with the merchant.

Confirm the direction. If the Z axis moves the wrong way, invert the direction in firmware or swap one phase pair.

Confirm the microstepping. The motor does not care about microstepping; the firmware and the driver must agree. A mismatch causes wrong step-per-unit values.

Troubleshooting the Replacement

After the mechanical swap, the most common issue is a misaligned coupler. If the motor whines but does not turn, the phase pairing is wrong. Use a multimeter to re-pair the wires.

If the Z axis moves but the bed drifts, the coupler set screw is loose. Re-tighten it. A loose coupler causes lost steps and layer shifts.

If the motor overheats, the current is set above the 2.8 A rating. Lower it. A hot motor loses torque and shortens its life.

If the bed grinds, the leadscrew is dry or the motor is under-torqued. Lubricate the leadscrew first. If the grinding persists, the motor is undersized.

If the Z axis is noisy, the motor may be resonating. Lower the acceleration or enable input shaping. The Tronxy listing does not prescribe a tuning profile; use your board's tool.

Post-Install Print Test

After the mechanical swap and the current setting, run a test print to confirm the Z axis holds position. A tall calibration cube is the simplest test: print a 50 mm cube and inspect the layers.

The layers should be even and consistent. If you see banding, the Z axis is not moving smoothly. Check the coupler alignment and the leadscrew lubrication.

If you see layer shifts, the motor is losing steps. Check the current setting against the 2.8 A rating. A driver starved of current stalls under load.

If the first layer is uneven, the bed is not level. Re-run the bed-leveling procedure. A new Z motor can shift the home position.

After the test print, run a 10-hour print to confirm the motor runs cool. Feel the motor periodically. It should be warm but not too hot to hold. If it is too hot, lower the current.

Final Reinstallation Checklist

Before you power on, double-check the mechanical fit. The motor face sits flat on the bracket. The four bolts are snug but not over-tightened. The coupler is seated on both shafts and the set screws are tight.

Check the wiring. The four wires form two phase pairs. Pair A goes to the A terminals, pair B to the B terminals. The connector is fully seated. The lead is routed away from the moving parts.

Check the current setting. The listing states 2.8 A class. The VREF formula is not published; confirm with the merchant. Set the driver to the confirmed value before powering on.

After power on, jog the Z axis at low speed. The motor should turn smoothly. If it buzzes, re-pair the phases. If it moves backwards, reverse one pair. Run a homing cycle.

After the homing cycle, run a 100 mm move. The bed should travel evenly. Feel the motor after ten minutes. It should be warm but not too hot to hold. If it is too hot, lower the current.

If You Get Stuck

If the motor does not turn after the swap, the phase pairing is the first suspect. Use a multimeter to re-pair. If the motor whines but does not move, the phases are split across the driver channels.

If the bed drifts, the coupler set screw is loose. Re-tighten it. If the Z axis is noisy, the leadscrew is dry or the motor is resonating. Lubricate the screw and lower the acceleration.

If you cannot set the current, the VREF formula is not published. Confirm with the merchant. Do not guess. A wrong current setting damages the winding.

If the bracket does not fit, you need an adapter. The NEMA 23 flange is 57 mm; the NEMA 17 is 42 mm. They are not interchangeable without an adapter plate.

The Final Verdict names Tronxy. The SL57STH56-2804A at $36.99 is the NEMA 23 choice when the system supports it. When stuck, the merchant is the fastest path.

Final Verdict: Which NEMA 23 Stepper Wins in 2026?

The Final Verdict names Tronxy. Replacing a tired 57 mm NEMA 23 on the X5SA-600 is a bolt-in job with the Tronxy SL57STH56-2804A at $36.99. The critical steps are documenting the wiring, aligning the coupler, setting the 2.8 A current, and jog-testing before a long print.

Power off, label the four wires, fit the Tronxy 57 mm motor, set the current to 2.8 A, and jog-test for ten minutes before your next large-format run.

Frequently Asked Questions

How do I remove the old X5SA-600 Z-axis motor?

Power off, unplug, unbolt the four screws, uncouple from the leadscrew, and unplug the four-wire lead. Support the motor as you remove the last bolt so it does not fall.

What tool do I need to replace the 57 mm motor?

A 4 mm Allen key for the mounting bolts, a 2.5 mm Allen key for the coupler set screws, and a multimeter for phase pairing.

How do I align the coupler on the X5SA-600?

Slide the coupler onto the motor shaft and the leadscrew. Tighten the set screw on the shaft side first, then the leadscrew side. Turn the leadscrew by hand; it should spin freely.

What current should I set on the new 57 mm motor?

The listing states 2.8 A class. The VREF formula is not published; confirm with the merchant before trimming the driver. Do not guess.

How do I pair the four wires to the driver?

Use a multimeter on resistance. Two wires that read a few ohms are one phase. Pair A goes to the A terminals, pair B to the B terminals.

My new motor buzzes and does not turn. What is wrong?

A phase pair is split across the driver channels. Re-check continuity with the multimeter and re-pair the wires.

The Z axis moves backwards after the swap. How do I fix it?

Reverse one phase pair (swap the two wires within one pair), or invert the direction in firmware. This is a one-minute fix.

Should I lubricate the leadscrew during the swap?

Yes. Clean the old grease and apply a thin film of lithium grease. A dry leadscrew makes the motor work harder and can cause stalls.

What is the return window for the 57 mm motor?

30 days by mail. If the motor is defective or does not fit, contact support within 30 days of delivery to arrange a return.

How do I test the new motor after installation?

Jog the Z axis at low speed. It should move smoothly. Run a homing cycle. Print a tall calibration cube and inspect the layers for evenness.

Article Keywords: nema 23 stepper motor, 57mm stepper, 2804a stepper, large format 3d printer motor, 2.8a stepper, nema23 vs nema17, x5sa-600 motor, tronxy stepper

How to Replace a 57mm NEMA23 Stepper Motor on a Tronxy X5SA-600 Large-Format Printer

RELATED ARTICLES